Type : C43 series Flame Proof coil, (for TORK solenoid valve)
Voltage : 220 VAC, 240 VAC, 110 VAC, 24 VAC, 12 VAC 50Hz / 60Hz
110 V DC, 48V DC, 24 V DC, 12 V DC,
Voltage tolerance : +/- %10
Coil Power : 15 VA For Alternative current coil standard production.
18 Watt (DC) for coil voltage
Protection Class : II 2 G Ex dII C T4 IP 67, Zone 1, zone 2, In processes where flame leakage is dangerous
Coil wire isolation : H class max. 180 C degree
Body material : Aluminum, Protection coated.
Coil filling : Atex resin
Operating ambient temperature: -10 °C,... 60 °C
Electrical connection : 3-pole terminal (Phase, Neutral and Earth)
Suitable gland size : M20 x 1.5, optional 1/2" NPT
Note: The product is sold without gland and cable.
Please give coil voltage in orders. See the coil section for detailed information.
Important warning: No idle energy should be given to the coil, energy should be given while it is on the valve
Coil grounding must be done in terms of safety.

Type NoCoil PowerVoltage AC / DCCopper Wire InsulationProtection ClassToleranceResponse Time
OpenClosed
C43220VAC15VA15 VA230 V ACH Class 180 °CII 2 G Ex dII C T4 IP 67.+/- %10400ms ≈ 1600ms1000ms ≈ 2000ms
C43220VAC24VA24 VA230 V ACH Class 180 °CII 2 G Ex dII C T4 IP 67.+/- %10400ms ≈ 1600ms1000ms ≈ 2000ms
C43110VAC15VA15 VA110 V ACH Class 180 °CII 2 G Ex dII C T4 IP 67.+/- %10400ms ≈ 1600ms1000ms ≈ 2000ms
C43024VAC15VA15 VA24V ACH Class 180 °CII 2 G Ex dII C T4 IP 67.+/- %10400ms ≈ 1600ms1000ms ≈ 2000ms
C43012VAC15VA15 VA12V ACH Class 180 °CII 2 G Ex dII C T4 IP 67.+/- %10400ms ≈ 1600ms1000ms ≈ 2000ms
C43024VDC18W18 W24V DCH Class 180 °CII 2 G Ex dII C T4 IP 67.+/- %10400ms ≈ 1600ms1000ms ≈ 2000ms
C43012VDC18W18 W12 V DCH Class 180 °CII 2 G Ex dII C T4 IP 67.+/- %10400ms ≈ 1600ms1000ms ≈ 2000ms
C43110VDC18W18 W110 V DCH Class 180 °CII 2 G Ex dII C T4 IP 67.+/- %10400ms ≈ 1600ms1000ms ≈ 2000m

Solenoid valves are energized by coils to open and close. When the solenoid is energized, it allows the core to move and operate the valve. Coils consist of cylindrical copper wire windings. When energized, the coil generates a magnetic flux. The coil fits into the coil housing and is secured with a nut.

TORK coils deliver superior performance with their unique design and are long-lasting. The C43 ATEX Metal-Protected Coil is specifically designed for flammable and explosive environments in Zone 1 and Zone 2. It is used in TORK ATEX solenoid valves and has an aluminum body.

It is developed for flammable, explosive, and hazardous environments and is manufactured in various AC and DC voltages. It is ATEX certified.

Protection class: II 2 G Ex d II T4 IP67
Application areas: Zone 1, Zone 2, processes at risk of flame leakage